HP MSA Fibre Channel and iSCSI drivers
======================================

The ``HPMSAFCDriver`` and ``HPMSAISCSIDriver`` Cinder drivers allow HP MSA
2040 or 1040 arrays to be used for Block Storage in OpenStack deployments.

System requirements
~~~~~~~~~~~~~~~~~~~

To use the HP MSA drivers, the following are required:

- HP MSA 2040 or 1040 array with:

  - iSCSI or FC host interfaces
  - G22x firmware or later

- Network connectivity between the OpenStack host and the array management
  interfaces

- HTTPS or HTTP must be enabled on the array

Supported operations
~~~~~~~~~~~~~~~~~~~~

- Create, delete, attach, and detach volumes.
- Create, list, and delete volume snapshots.
- Create a volume from a snapshot.
- Copy an image to a volume.
- Copy a volume to an image.
- Clone a volume.
- Extend a volume.
- Migrate a volume with back-end assistance.
- Retype a volume.
- Manage and unmanage a volume.

Configuring the array
~~~~~~~~~~~~~~~~~~~~~

#. Verify that the array can be managed via an HTTPS connection. HTTP can also
   be used if ``hpmsa_api_protocol=http`` is placed into the appropriate
   sections of the ``cinder.conf`` file.

   Confirm that virtual pools A and B are present if you plan to use virtual
   pools for OpenStack storage.

   If you plan to use vdisks instead of virtual pools, create or identify one
   or more vdisks to be used for OpenStack storage; typically this will mean
   creating or setting aside one disk group for each of the A and B
   controllers.

#. Edit the ``cinder.conf`` file to define a storage back end entry for each
   storage pool on the array that will be managed by OpenStack. Each entry
   consists of a unique section name, surrounded by square brackets, followed
   by options specified in a ``key=value`` format.

   * The ``hpmsa_backend_name`` value specifies the name of the storage pool
     or vdisk on the array.

   * The ``volume_backend_name`` option value can be a unique value, if you
     wish to be able to assign volumes to a specific storage pool on the
     array, or a name that is shared among multiple storage pools to let the
     volume scheduler choose where new volumes are allocated.

   * The rest of the options will be repeated for each storage pool in a given
     array: the appropriate Cinder driver name; IP address or host name of the
     array management interface; the username and password of an array user
     account with ``manage`` privileges; and the iSCSI IP addresses for the
     array if using the iSCSI transport protocol.

   In the examples below, two back ends are defined, one for pool A and one for
   pool B, and a common ``volume_backend_name`` is used so that a single
   volume type definition can be used to allocate volumes from both pools.

   **iSCSI example back-end entries**

   .. code-block:: ini

      [pool-a]
      hpmsa_backend_name = A
      volume_backend_name = hpmsa-array
      volume_driver = cinder.volume.drivers.san.hp.hpmsa_iscsi.HPMSAISCSIDriver
      san_ip = 10.1.2.3
      san_login = manage
      san_password = !manage
      hpmsa_iscsi_ips = 10.2.3.4,10.2.3.5

      [pool-b]
      hpmsa_backend_name = B
      volume_backend_name = hpmsa-array
      volume_driver = cinder.volume.drivers.san.hp.hpmsa_iscsi.HPMSAISCSIDriver
      san_ip = 10.1.2.3
      san_login = manage
      san_password = !manage
      hpmsa_iscsi_ips = 10.2.3.4,10.2.3.5

   **Fibre Channel example back-end entries**

   .. code-block:: ini

      [pool-a]
      hpmsa_backend_name = A
      volume_backend_name = hpmsa-array
      volume_driver = cinder.volume.drivers.san.hp.hpmsa_fc.HPMSAFCDriver
      san_ip = 10.1.2.3
      san_login = manage
      san_password = !manage

      [pool-b]
      hpmsa_backend_name = B
      volume_backend_name = hpmsa-array
      volume_driver = cinder.volume.drivers.san.hp.hpmsa_fc.HPMSAFCDriver
      san_ip = 10.1.2.3
      san_login = manage
      san_password = !manage

#. If any ``volume_backend_name`` value refers to a vdisk rather than a
   virtual pool, add an additional statement ``hpmsa_backend_type = linear``
   to that back end entry.

#. If HTTPS is not enabled in the array, include ``hpmsa_api_protocol = http``
   in each of the back-end definitions.

#. If HTTPS is enabled, you can enable certificate verification with the option
   ``hpmsa_verify_certificate=True``. You may also use the
   ``hpmsa_verify_certificate_path`` parameter to specify the path to a
   CA\_BUNDLE file containing CAs other than those in the default list.

#. Modify the ``[DEFAULT]`` section of the ``cinder.conf`` file to add an
   ``enabled_back-ends`` parameter specifying the backend entries you added,
   and a ``default_volume_type`` parameter specifying the name of a volume type
   that you will create in the next step.

   **Example of [DEFAULT] section changes**

   .. code-block:: ini

      [DEFAULT]
      enabled_backends = pool-a,pool-b
      default_volume_type = hpmsa


#. Create a new volume type for each distinct ``volume_backend_name`` value
   that you added in the ``cinder.conf`` file. The example below assumes that
   the same ``volume_backend_name=hpmsa-array`` option was specified in all
   of the entries, and specifies that the volume type ``hpmsa`` can be used to
   allocate volumes from any of them.

   **Example of creating a volume type**

   .. code-block:: console

      $ openstack volume type create hpmsa
      $ openstack volume type set --property volume_backend_name=hpmsa-array hpmsa

#. After modifying the ``cinder.conf`` file, restart the ``cinder-volume``
   service.

Driver-specific options
~~~~~~~~~~~~~~~~~~~~~~~

The following table contains the configuration options that are specific to
the HP MSA drivers.

.. include:: ../../tables/cinder-hpmsa.inc